  1. On new construction or renovations projects, inside wiring installation would take place before internal wall boarding commences.  This will simplify installation, minimize costs and inconvenience, improve overall appearance and help to protect the wiring.
  2. For the protection of your communications equipment, life and building, TELUS Communications Inc. will require a No. 6 green insulated A.W.G. ground wire at the protector terminal.  This ground wire shall be connected to a suitable building ground electrode and installed as per The Canadian electrical Code, Part 1.

 