- All aerial entrance conduit for residential buildings covered in
this section shall be rigid galvanized steel (mast), electrical
metallic tubing (E.M.T.) or rigid P.V.C UV. This conduit
is for TELUS Communications Inc. services only. (Must meet The
Canadian Electrical Code Requirements Part 1). All underground
conduit shall be P.V.C. DBII orange.
- The entrance conduit size shall be determined by the number of dwelling
units in the building as identified below.
| SIZE OF CONDUIT (mm) |
| NO. OF DWELLING UNITS IN BUILDING |
BURIED ENTRANCE |
AERIAL ENTRANCE
(No Mast) |
| 3 & 4 |
50mm |
32mm |
- Buildings of 3 and 4 units require a CSA approved weatherproof
enclosure complete with a 19mm plywood backboard. The inside
wire must enter enclosure bottom right corner.
- For grounding requirements refer to Section
3 Grounding Requirements.

Detail "A"
Approved Service Head Fitting

Date Controlled Material