  1. A 1.83M x 102mm x 102mm (6' x 4" x 4") treated service post or approved equivalent shall be provided adjacent to the mobile home at the point of service entry.  The post shall be set 610mm (24") into the ground no more that 610mm (24") from the mobile unit, and is unacceptable if placed underneath the unit.
  2. Necessary trenching and backfilling for the establishment of buried cable distribution and network services shall be carried out in accordance with the provisions outlined in Residential Buildings Up to Two Dwelling Units. (Sec. 3).
  3. TELUS Communications Inc. shall place buried wiring from its main network service connection location to the Service Provider Demarcation Point on the approved service post.
  4. For grounding requirements refer to Section 3 Grounding Requirements.

Date Controlled Material