  1. A  Class 6 treated pole shall be provided adjacent to the mobile home at the point of service entry.  The treated post shall be set 1.22M (4') into the ground no more than 610mm (2') from the mobile unit.
  2. TELUS Communications Inc. shall attach its network service wire to the service post, and to the protector terminal/CCP.
  3. TELUS Communications Inc. will not install service wiring hooks, straps, clamps or any other wire fastening devices on the exterior walls, roof, or floor of mobile homes.
  4. For grounding requirements refer to Section 3 Grounding Requirements.